PURESOURCE 3
TM
ICE AND WATER FILTER SYSTEM
SYSTEM SPECIFICATION AND DATA SHEET
APPLICATION GUIDELINES / CONDITIONS OF USE
Water Supply:
Water Temp.:
Water Pressure:
Municipal or Well applications
Maximum 100° F (38° C), Minimum 33° F (0.6° C); for cold water use only.
100 psi Maximum. Recommended Minimum: 30 psi, as measured at the valve inlet.
Timely cartridge replacement is essential for the product to perform as advertised. Please refer to the Use & Care Guide for general operation and •
maintenance requirements. Your refrigerator will have an electronic light on the freezer door dispenser that lights up yellow or displays “ORDERwhen
thelterisalmostreadyforreplacementandlightsupredordisplays“REPLACE”whentheltermustbereplaced.Theindicatorbuttonispressed
forapproximately3-10secondstoresetafterreplacingtheltercartridge.PleaserefertotheUse&CareGuideforcompleteinstructions.Flushnew
cartridge for 4 minutes.
PureSource 3•
TM
Ice&WaterFilterSystemshouldnotbeusedonwaterthatismicrobiologicallyunsafeorwithwaterofunknownqualitywithout
adequatedisinfectionbeforeorafterthesystem.Systemmaybeusedondisinfectedwatersthatmaycontainlterablecysts.
Whiletestingwasperformedunderstandardlaboratoryconditions,actualperformancemayvarybasedonlocalwaterconditionsand/orpressure.High•
sedimentareasmayrequiremorefrequentltercartridgereplacement.
PureSource 3•
TM
WaterFiltrationSystemwillabsorbbadtastesandodorsinbothicecubesanddrinkingwater.
SYSTEM SPECIFICATIONS
Flow Rate:
Capacity:
System Construction:
IceMaker-3.4to4.3oz(99-125cc)per6.3secondsat60psi(asmeasuredatvalveinlet)
Dispenser-60ozperminute(.5gpmor1.9litersperminute)at60psi(asmeasuredatvalveinlet)
200Gallons
FilterHousingAssembly-PolycarbonatePlastic
WaterStorageTank-PolyethylenePlastic
Tubing-PolyethylenePlastic
FilterMedia-ExtrudedCarbonblock
REPLACEMENT CARTRIDGE INFORMATION
ReplacementWF3CBcartridgesareavailablethroughyourlocalFrigidairedealerorbycallingtheCustomerAssistanceCenterat1-800-944-9044.
Please reference installation instructions in the Use & Care Guide for replacing the cartridge and warranty information. Estimated cost for the replace-
mentltercartridgekit:Lessthan$40.00.
PERFORMANCE DATA SHEET
MODEL:PureSource 3
TM
Usethereplacementcartridgelistedbelow.
The PureSource 3
TM
systemwiththeWF3CBcartridgehasbeentestedaccordingtoNSF/ANSIStandard
42/53forthereductionofsubstanceslistedbelow.Theconcentrationoftheindicatedsubstancesinwater
enteringthesystemwasreducedtoaconcentrationlessthanorequaltothepermissiblelimitforwater
leavingthesystem,asspeciedinNSF/ANSIStandard42/53.
Generaltestwaterparameters;pH=7.5+/-0.5Temp.20°C+/-3°C(68°F+/-5°F)Pressure=60psi
P.O.Box212378
Augusta,GA30907
2009ELECTROLUXHOMEPRODUCTS,INC.
242070200
Substance
Reduction
NSF Standard NSF Reduction
Requirements
InuentChallengeCon-
centration
Max.Permissable
Product Water
Concentration
Average%
Reduction
Chlorine taste & odor 42 >/=50% 2.0±10%mg/L NA 97.40%
Chlorobenzene 53 N/A 2.0±10%mg/L 0.1mg/L 99.90%
Cyst 53 99.95% Min50,000/L N/A 99.95%
2,4-D 53 N/A 0.210±10%mg/L 0.07mg/L 94.50%
Alachlor 53 N/A 0.04±10%mg/L 0.002mg/L 97.50%
Atrazine 53 N/A 0.009±10%mg/L 0.003mg/L 94.00%
Lead 53 N/A 0.15±10%mg/L 0.01mg/L 99.10%
Mercury 53 N/A 0.006±10%mg/L 0.002mg/L 80.40%
Lindane 53 N/A 0.002±10%mg/L 0.0002mg/L 99.00%
O-dichlorobenzene 53 N/A 1.8±10%mg/L 0.6mg/L 99.90%
Toxaphene 53 N/A 0.015±10%mg/L 0.003mg/L 93.50%
Particulate class l 42 >/=85% Min10,000particles/ml >/=85% 99.90%
Turbidity 53 N/A 11±NTU 0.5NTU 98.50%
Styrene 53 N/A 2.0±10% 0.1mg/L 99.90%
Tetrachloroethylene 53 N/A 0.015±10% 0.005mg/L 99.60%
8.5 x 11 50# offset
black ink
printed on two sides
Page view 0
1 2

Summary of Contents

Page 1 - 8.5 x 11 50# offset

PURESOURCE 3TM ICE AND WATER FILTER SYSTEMSYSTEM SPECIFICATION AND DATA SHEETAPPLICATION GUIDELINES / CONDITIONS OF USEWater Supply:Water Temp.:Water

Page 2 - 202509

State of CaliforniaDepartment of Public HealthWater Treatment DeviceCertificate NumberDate Issued: December 15, 2009Trademark/Model DesignationReplac

Comments to this Manuals

No comments