INSTALLATION SPECIFICATIONS
Product Shipping Weight (approx.) – 215 Lbs.
Single phase 3- or 4-wire cable, 120 / 240 or 120 / 208 Volt, 60 Hertz, fused
on both sides of line with ground.
Connected Load (kW Rating) @ 240 / 208 Volts = 13.5 / 10.5 kW
Recommended Circuit Breaker – 40 Amps
Always consult local and national electric codes.
Make sure wall coverings around range can withstand heat generated
by range.
Floor beneath range MUST be solid and level.
Overhead cabinetry should not exceed a 13" maximum depth.
Absolute minimum horizontal distance between overhead cabinets installed to
either side of appliance must be no less than maximum width of appliance.
Range can be installed flush to wall with 0" minimum rear clearance.
Minimum 1" clearance required from edge of rangetop to nearest combustible
wall on either side of range above 36" height.
Allow 30" minimum clearance between top of cooking surface and bottom
of unprotected wood or metal overhead cabinet; or 24" minimum clearance
when bottom of wood or metal overhead cabinet is protected by not less than
1/4" flame retardant millboard covered with not less than No. 28 MSG sheet
steel, 0.015" stainless steel, 0.024" aluminum or 0.020" copper.
To reduce risk of fire when using overhead cabinetry, install range hood
that projects horizontally a recommended minimum of 5" beyond bottom
of cabinets.
Follow all dimension requirements provided to prevent property damage,
potential fire hazard, and incorrect countertop and
cabinet cuts.
Specifications subject to change. Accessories information available on the web at frigidaire.com
Note: For planning purposes only. Always consult local and national electric, gas and plumbing codes.
Refer to Product Installation Guide for detailed installation instructions on the web at frigidaire.com.
30" Induction Freestanding Ranges (Storage or Warmer Drawer)
Gallery
Front
29
7
/8"
48"
max.
30" min.
13"
max.
25"
24"
Minimum
1" clearance
required
to nearest
combustible
wall on
either side
of range
above 36"
height
30"
6"
C
L
22"
11"
36"
stand.
30"
min.*
Wall
18"
min.
18"
min.
*Note: 30" minimum clearance between top of cooking
surface and bottom of unprotected wood or metal
overhead cabinet; or 24" minimum clearance when
bottom of wood or metal overhead cabinet is protected
by not less than 1/4" flame-retardant millboard covered
with not less than No. 28 MSG sheet steel, 0.015"
stainless steel, 0.024" aluminum or 0.020" copper.
0" clearance is minimum for rear of range. Follow all
dimension requirements provided above to prevent
property damage, potential fire hazard, and incorrect
countertop and cabinet cuts.
Side
49"
26
1
/2"
30
"
36"
(Adjustable
to
±
1
/8")
Shaded area allows for flush-to-wall
installation of rear wall electrical
outlet. (All dimensions for outlet
location are maximum.)
2
5
/8" for warmer drawer models or
3
1
/2" for storage drawer models
Note: Overall
product dimensions
are model specific
and may vary slightly
from illustration. Refer
to model’s product
specifications for
actual dimensions.
Power supply
connection
(middle bottom rear*)
*when viewed from front
FGIF3036T D/F
FREESTANDING RANGE
30" INDUCTION
Page view 2
1 2 3

Comments to this Manuals

No comments