Top Load Laundry Center
FFLG2022MW Gas
Specifications
subject to change.
USA
10200 David Taylor Drive
Charlotte, NC 28262
1-800-FRIGIDAIRE
frigidaire.com
CANADA
5855 Terry Fox Way
Mississauga, ON L5V 3E4
1-800-265-8352
frigidaire.ca
FFLG2022M 10/13 © 2013 Electrolux Home Products, Inc.
Top Load Laundry Center Specifications
Product Shipping Weight (approx.) – 275 Lbs.
Designed for HOME USE only, not recommended for commercial
application.
An electrical supply with grounded three-prong receptacle is
required. The power supply circuit must be installed in accordance
with current edition of National Electrical Code (ANSI/NFPA 70)
and local codes & ordinances.
Voltage Rating – 120V / 60 Hz / 15 Amps
Amps @ 120 Volts = 13 Amps
Connected Load (kW Rating) @ 120 Volts = 1.03 kW
Unit equipped with 120V 3-wire power supply cord, approx, 60" long.
Always consult local and national electric, plumbing & gas codes.
Can be installed in recess or closet requiring 0" minimum installation
clearance around sides and back of unit. To achieve 0" minimum rear
clearance, dryer MUST be vented straight back. Closet installation
requires additional 1" minimum clearance between front of unit
and vented door. Door MUST be vented with 120 sq. in. minimum
louvered opening, equally divided, located 3" from top and bottom
of door. A louvered door with equivalent air openings for full-length
of door is acceptable. Air openings MUST remain unobstructed with
door installed. (For additional installation details, refer to Product
Installation Guide on web.)
Do NOT install in area exposed to dripping water or outdoor weather
conditions; where gasoline or other flammables are kept or stored; or
where dryer comes in contact with curtains, drapes or anything that
will obstruct flow of combustion and ventilation air.
For garage installation, dryer MUST be located minimum 18" above floor.
Floor MUST be solid with 1" maximum slope. Do NOT install on
carpeted surface.
Dryer MUST exhaust to outside of building, NOT into any concealed
space.
Exhaust installation requires minimum 4"-diameter rigid or semi-rigid
metal duct with approved, unobstructed vent hood having swing-out
damper(s). If installing rigid metal duct (preferred), do not exceed
MAXIMUM venting run length of 56 ft., allow deductions for elbows
and vents. If installing semi-rigid metal duct, do not exceed MAXIMUM
venting run length of 8 ft., always allow deductions for elbows and
vents (Refer to Product Installation Guide on web for additional
information). Do NOT use flexible plastic or metal foil duct and use
shortest run possible.
Flush-to-wall installation allows for 4-way exhausting — straight back,
down, left and right. While vertical exhausting is acceptable, certain
circumstances could affect dryer’s performance; and unit will be
positioned 4-1/2" from wall. (Flush-to-wall exhausting may be done
by going below dryer, then sideways.)
H/C water faucets MUST be installed within 42" of washer’s water
inlet and MUST be 3/4" with threading for laundry hose connection
to connect to 48" inlet hoses.
Water pressure MUST be between 10 and 120 psi with NOT more
than 10 psi pressure difference between hot and cold.
Drain standpipe requires diameter of 1-1/4" min. and height of
33" min. / 96" max. above floor, capable of eliminating 17 gallons
per minute. Attached 52" drain hose can reach 74"-high standpipe.
For higher standpipe, optional Drain Hose Extension Kit available.
Gas supply line should be 1/2" pipe and MUST have individual
shutoff valve.
Leveling legs supplied to level dryer properly and reduce excessive
noise and vibration.
For manufactured or mobile home installation optional Mobile Home
Installation Kit (PN # 137067200) required. (For specific installation
details, refer to Product Installation Guide on web.)
Note: For planning purposes only. Refer to Product Installation Guide
on the web at frigidaire.com for detailed instructions.
Optional Accessories
Mobile Home Installation Kit – (PN # 137067200).
Drain Hose Extension Kit – (PN # 134592700).
LP Gas Conversion Kit – (PN # PCK3100).
Drying Rack – (PN # DRLC).
Top Load Laundry Center - Gas (GLGT1031F)