PPOOSSIITTIIOONN
Place the freezer horizontally on a firm surface, resting on
all four plastic feet. Use a wooden block or similar object
to compensate for any bumps/holes in the surface.
The room should be dry and adequately ventilated.
If the room temperature exceeds 32°C, or falls below
freezing point, the freezer will not function as it should.
Do not place the freezer close to sources of heat,
radiators, chimneys, etc., and do not place the freezer in
direct sunlight.
If the freezer has been handled standing on end it should
be allowed to stand in normal position for about 12 hours
before switching it on.
Please ensure that when the appliance is installed it is
easily accessible for the engineer in the event of a
breakdown.
SSWWIITTCCHHIINNGG OONN
Before switching on, the freezer should be cleaned inside.
See under Maintenance.
Set the thermostat knob in middle position. Allow the
freezer to run for several hours before placing food inside.
The green light is illuminated as long as the freezer is
connected.
EELLEECCTTRRIICCAALL RREEQQUUIIRREEMMEENNTTSS
Before switching on, make sure that the voltage of your
electricity supply is the same as that indicated on the rating
plate, located inside the lid.
For your convenience, this appliance comes complete with
either a moulded-on or re-wireable 13 amp (BS1363) plug,
protected by a 13 amp ASTA approved (BS1362) fuse.
In the event of having to change the fuse in the plug
supplied, a replacement 13 amp ASTA approved (BS1362)
fuse must be used.
In the case of a moulded-on plug, the fuse cover MUST be
refitted after changing fuse. If the fuse cover is lost or damaged
the plug MUST NOT be used until a replacement is obtained.
Replacement covers are avaliable from your local electricity
shop or nearest customer service centre. The colour of the
replacement fuse cover must match the colour insert or
emboss on the base of the plug.
In the case of a re-wireable plug care must be taken to
ensure that the top cover is refitted without causing damage
to either the top cover or base. In the event of the plug
becoming damaged or cracked, it must be replaced with an
equivalent 13 amp, BS1363 approved plug (ref. fig. 1) and
rewired using the following procedure:
4
INSTALLATION
Warning:
This appliance must be earthed.
Thermostat knob
Green light
IMPORTANT
The wires in the mains lead are coloured in
accordance with the following code:
Green and Yellow Earth
Blue Neutral
Brown Live