Frigidaire FPHB2899PF User Manual

Browse online or download User Manual for Kitchen Frigidaire FPHB2899PF. FRIGIDAIRE FPHB2899PF User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 2
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
SERVICE DATA SHEET
A00606101
ICE & WATER - AUTOMATIC DEFROST
BOTTOM FREEZER - R134a
CAUTION
All electrical parts and wiring must be shielded from torch flame. DO NOT allow
torch to touch insulation; it will char at 200°F and flash ignite (burn) at 500°F.
Excessive heat will distort the plastic liner.
PERFORMANCE DATA NO LOAD & NO DOOR OPENINGS AT 37°/0°
CONTROL SETTING
Type A with Run / Start Capacitor 65°F (18°C) Ambient 90°F (32°C) Ambient
Operating Time
90 to 100% 100%
Freezer Temperature -5° to 2°F (-20° to -17°C) -1° to 3°F (-18° to -16°C)
Refrigerator Temperature 34° to 39°F (1° to 4°C) 34° to 39°F (1° to 4°C)
Low Side Pressure -2 to 6 psig ( -14 to 41 kPa) -2 to 6 psig (-14 to 41 kPa)
High Side Pressure (last 1/3 cycle) 85 to 105 psig (586 to 724 kPa) 120 to 135 psig (827 to 931 kPa)
Wattage (last 1/3 cycle) 30 to 50 50 to 70
Amps (running)
.4 to .8 .7 to .9
Base Voltage 115 vac (127 vac max)
DEFROST SPECIFICATIONS
Cabinet Size
Thermostat Heater
Cut-in Cut-out Watts Ohms
26’ & 28’ SD, 23’ CD 25°F (-4°C) 47°F (8°C) 500 26.5
Electronic Timer - (ADC) Defrost 24 minutes every 6-96 hours of compressor run time.
CONDENSER FAN MOTOR
Watts RPM Amps
3.1 1100 CW Opposite Shaft 0.03 Running
FREEZER ICE MAKER SPECIFICATIONS
Electrical 115 vac (127 vac max)
Thermostat Opens at 48°F ( 9°C), Closes at 15° F ( -9°C)
Heater Voltage 115 vac
FREEZER ICE MAKER CONNECTOR PLUG CONNECTIONS
Wire Number Wire Color Connects to:
1 Green / Yellow Ground
2 Yellow Water Valve
3 Black Line
4 Light Blue Neutral
IMPORTANT SAFETY NOTE
The information provided herein is designed to assist qualified repair personnel only. Untrained persons should not
attempt to make repairs due to the possibility of electrical shock. Disconnect power cord before servicing this appliance.
IMPORTANT
If any green grounding wires are removed during servicing, they must be returned to their original position and
properly secured.
System Diagnostic Mode
Activate:
Press freezer + and fresh food + for up to 10 sec. simultaneously.
Deactivate:
Press fresh food + for up to 10 sec. Diagnostic Mode will automatically deactivate after 5 min. of inactivity.
Note: Silence alarm.
• Tests marked with “*” may not be applicable to this unit and will not be displayed in System Diagnostic Mode.
• Tests displayed in diagnostic mode but not described below are for internal purposes only; advance through.
• View UI display for “on,” “off,” “CL,” “OP,” “SH,” “LO,” “HI” or numerical results of tests.
• Listen for operating sounds; feel for heat or air ow as appropriate to determine results of tests.
Test To activate test: Passing result
-- First Screen -- All LED lights on UI illuminated
-- Second Screen -- All segments on UI temperature displays illuminated
-- Third Screen -- Blank UI display, no lights illuminated, no shadowing; “-” and “+” blinking on
FF display side to show location.
28 Dispenser Paddle Press disp. paddle “on” on UI when depressed; “off” when released
1* Standard
Compressor
Press set Compressor running when “on”; stopped when “off”
2 Defrost Heater Press set Defrost limit switch must be closed; verify “CL” in test 26.
Feel for heat from defrost heater when “on”.
If “OP” in test 26, heater will not activate.
3 FF Light Press set With FF door open, FF lights on when “on”; off when “off”
8 Water Valve
(Dispenser)
Press set
Be prepared to collect water at dispenser.
Water dispenses when “on”; stops when “off”
9 FZ Light Press set With FZ door open, FZ lights on when “on”, off when “off”
10 Auger Motor Press set FF door must be closed.
Motor running when “on”; motor stopped when “off”
11 Cube/Crush
Solenoid
Press set FF door must be closed. Do not leave solenoid in activated state.
Solenoid activated when “on”; deactivated when “off”
41* Perfect Temp Drawer
(PTD)
Press set PTD UI illuminated when “on”, off when “off”
12* VCC Condenser Fan Press set Fan running when “on”; stopped when “off”
38* VCC Compressor Press set Compressor running when “on”; stopped when “off”
15 Evaporator Fan Press set Fan running for minimum of 10 sec. when “LO” or “HI”; stopped when
“off”. Feedback failure if fan starts but runs less than 10 sec. Listen for speed
change from “LO” to “HI”.
36 Ice Chute Door Depress ice chute door
or press set
“OP” on UI when manually opened; “CL” when closed. Or, using “set,””OP”
on UI when fully opened or “CL” when fully closed by the motor.
22 Damper Press set With inspection mirror, observe damper open when “OP”; closed when “CL”
23 FF Door Open/close FF door “CL” on UI when door closed; “OP” when open
24 FZ Door Open/close FZ door “CL” on UI when door closed; “OP” when open
26 Defrost Limit Switch Activates automatically “CL” on UI when closed; “OP” when open
29 FF Thermistor Mid-
level
Activates automatically UI shows temperature sensed by FF thermistor; pass if within 10°F of tem-
perature measured with gauge at mid-level FF thermistor location.
“OP-” if open; “SH-” if short
30 FZ Thermistor Activates automatically UI shows temperature sensed by FZ thermistor; pass if within 10°F of temperature
measured with gage at FZ thermistor location.
“OP” if open; “SH” if short
33 Ambient Thermistor
@ Main Board
Activates automatically UI shows temperature sensed at main board; pass if within +20°F/-10°F of
temperature measured with gauge at main board location.
“OP” if open; “SH” if short
35* FF Thermistor
Upper-Level
Activates automatically UI shows temperature sensed by upper level FF thermistor; pass if within 10°F
of temperature measured with gauge at upper-level FF thermistor location.
“OP¯” if open; “SH¯” if short
34* Ambient Thermistor
@ UI
Activates automatically UI shows temperature sensed at UI; pass if within +20°F/-10°F of tempera-
ture measured with gauge at UI location. “OP” if open; “SH” if short
46 Humidity Sensor Activates automatically “OP” if open, “SH” if short
AC Heater System: Displays %RH
DC Heater System: “HI” – heater should be on
“Lo” – heater should be off
%RH is displayed when humidity is between “Lo” and “HI” values; heater
could be on or off.
47* Dispenser
Pocket Heater
Press set AC Heater System: “--” ; test not available
DC Heater System: heater on when “on”, off when “off”
0- Firmware
Parameters
Press set Displays digit sequence; record
2- Main Board
Firmware
Press set Displays digit sequence; record
4- UI Firmware Press set Displays digit sequence; record
Variable Capacity Compressor (VCC) Diagnostics (select models)
If test 38 fails, diagnose as follows:
Replace Inverter Board
Check at Inverter Board on
Compressor
(BLK and RED wires)
Is Inverter Board receiving 10-15
VAC and 1-5 VDC from Main
Control Board?
Check at Main Control Board
(BLK/WHT and RED/BLK wires)
Is Main Control Board sending
10-15 VAC and 1-5 VDC to
Inverter Board?
no
Check at the connector from the power cord
harness into the inverter board, located in
the machine compartment.
(PUR and WHT wires)
Is Inverter Board receiving 115 VAC
from power supply?
Check voltage supply.
Check and repair power
cord harness wiring and
connections.
no
Identify and repair damaged wires or
poor connections between Main Control
Board and Inverter Board.
yes
Remove inverter box from the
compressor and check resistance
across compressor winding pairs as
shown.
Is resistance across all winding
pairs equal?
Replace Compressor and
Inverter Board.
no
Check connections from Inverter
Board to Compressor
Are connections from Inverter
Board to Compressor intact?
yes
Identify and repair damaged
wires or poor connections
between Inverter Board and
Compressor.
no
VCC Resistance Check
Check resistance between terminals 1 and
2, 2 and 3, 3 and 1.
If all resistances are equal,
compressor is operative.
Replace Main Control Board.
no
yes yes
yes
Error Codes Special Modes
Display
Interpretation Mode
Display Activate/Deactivate
(press for up to 10 sec. simultaneously)
FZ FF FZ FF
-- OP Open FF Thermistor Manual Defrost d F + and - / same to deactivate
OP -- Open FZ Thermistor Display / Showroom 77 77 ٨ and - / Power-on-Reset (POR)
-- SH Shorted FF Thermistor Sabbath Sb Sb ٧ and + / same to deactivate
SH --
Shorted FZ Thermistor System Diagnostic No FF or FZ display, all
UI LEDs on.
٨ and ٧/ + to deactivate
SY CF
UI to Main Control
Board communication
failure; on start up
FFIM Diagnostic Numerical display of
first test
٨ and + together to activate /
press and hold + to deactivate
SY CE
UI Main Control Board
communication error; after
a period in operation
Notes:
• Always check for pin back-outs, pinched or damaged wires before replacing components.
• Determine whether failure is caused by the component, main control board or wiring.
Contact TID before replacing main control board.
Refer to Service Manual for additional information.
SY EF Evaporator Fan Failure
Fresh Food Ice Maker Diagnostic Mode
Activate: Press freezer + and fresh food + temperature pads for up to 10 sec. simultaneously.
Press + or - to move forward or backward through tests.
Deactivate: Press fresh food + for up to 10 sec. FFIM Diagnostic Mode will automatically deactivate after 5 min. of inactivity.
NOTE: Silence alarm.
Test
To activate test
Passing Result
52C Ice Maker Thermistor Activates
automatically
FZ display shows temperature sensed by Ice Maker Thermistor.
“OP” if open; “SH” if short
55C Water Valve Set Remove ice tray to collect water into a measuring container to measure water
fill. If collecting water into ice tray, first perform test 63C to empty ice tray.
57C Evaporator Fan (FFIM) Set “On” on FZ display when fan activated, “OFF” when deactivated.
58C
Ice Level Sensor Activates
automatically
Remove ice bucket.
Allow bail arm to drop freely. Pass if no alarm when tray returns to “home” position.
Hold bail arm up. Pass if alarm sounds when tray returns to “home” position.
This test runs continuously until another test is selected.
63C Twist Tray Set Remove ice bucket.
FZ display shows “1” and “GOOD”.
IMPORTANT: PLEASE RETURN THIS SHEET TO ITS ORIGINAL LOCATION.
FREEZER ICE MAKER INFORMATION
(Where Applicable)
Test Cycling: Remove cover by inserting screwdriver in notch at bottom and prying cover from housing. Use
screwdriver to rotate motor gear counterclockwise until holding switch circuit is completed. All components of
ice maker should function to complete the cycle.
Water Fill Volume: The water fill adjustment screw will change the fill time. One full turn is equal to 20cc (.68 oz.).
The correct fill is 102 to 130cc (3.4 to 4.3 oz.). When a water valve is replaced, the fill volume must be checked.
T
U
R
N
Mounting
Plate
Screws
Mounting
Plate
Screw
Motor
Gear
Timing
Gear
Water Fill
Adjustment
Page view 0
1 2

Summary of Contents

Page 1 - IMPORTANT SAFETY NOTE

SERVICE DATA SHEETA00606101ICE & WATER - AUTOMATIC DEFROSTBOTTOM FREEZER - R134a CAUTIONAll electrical parts and wiring must be shielded from to

Page 2 - Wire Diagram 242292601

Wire Diagram 242292601

Related models: FPHF2399PF

Comments to this Manuals

No comments