30" ELECTRIC SLIDE-IN RANGE INSTALLATION INSTRUCTIONS
Four Conductor Wire Connection to Range
Where local codes does NOT permit connection of the
frame grounding conductor to the neutral wire of the
copper power supply cord (see Figure 4):
1. Removethescrewwhichisxingtherearwire
cover, then remove the rear wire cover (access
cover) to expose range terminal connection block
(see Figure 2).
2. Remove the grounding strap from the terminal
block and from the appliance frame.
3. Using the nuts supplied with the literature package,
connect the ground wire (green) of the copper
power supply cord to the frame of the appliance with
the ground screw, using the hole in the frame where
the ground strap was removed (see Figure 4).
4. Connect the neutral of the copper power supply
cord to the center silver-colored terminal of the
terminal block, and connect the other wires to the
outer terminals. Match wires and terminals by color
(red wires connected to the right terminal, black
wires connected to the left terminal).
5. Put back the rear wire cover using the screw
removed on step 1.
Terminal Block
Silver Colored Terminal
Red
Wire
Neutral
(White Wire)
Ground (Bare
Copper Wire)
To 240 V
Receptacle
A User Supplied
Strain-relief Must
Be Installed at
This Location
Black Wire
1 1/8" (2,9
cm) Dia.
Direct
Connection
Hole. Punch
Out Knockout
for 1 3/8" (3,5
cm) Dia. Cord
Kit Hole.
NOTE: Be sure to remove
the supplied grounding strap.
Figure 4
5.
Electrical Connection to the
Range (U.S.A.)
Three Conductor Wire Connection to
Range
If local codes permit connection of the frame grounding
conductor to the neutral wire of the copper power
supply cord (see Figure 3):
1. Removethescrewwhichisxingtherearwire
cover, then remove the rear wire cover (access
cover) to expose range terminal connection block
(see Figure 2).
2. Using the nuts supplied in the literature package,
connect the neutral of the copper power supply
cord to the center silver-colored terminal of the
terminal block, and connect the other wires to the
outer terminals. Match wires and terminals by color
(red wires connected to the right terminal, black
wiresconnectedtotheleftterminal)(seegure3).
3. Put back the rear wire cover using the screw
removed on step 1.
Figure 3
Silver Colored Terminal
1 1/8" (2,9 cm) Dia.
Direct Connection
Hole. Punch Out
Knockout for 1 3/8"
(3,5 cm) Dia. Cord
Kit Hole.
To 240 V
Receptacle
A User Supplied
Strain-relief Must
Be Installed at This
Location.
Black
Wire
Terminal
Block
Cord
Mounting
Plate
Neutral
(White Wire)
Grounding
Strap
Red Wire