SERVICE DATA SHEET
A06686901
FREEZER ICE MAKER - AUTOMATIC DEFROST
BOTTOM FREEZER - R134a
POWER
ICE MAKER
I
CE MAKER
ICE MAKER
WATER VALVE
LINE
THERMAL
CUT-OUT
HOLD
SWITCH
THERMOSTAT
SHUTOFF
SWITCH
WATER FILL
SWITCH
MOLD HEATER
MOLD
MOUNTING
PLATE
165 WATTS
MOTOR
NEUTRAL
BLK
BLK
BLK
BLU
C
C
C
NO
NO
NO
NC
NC
NC
YELLOW
BRN
RED
GRN / YEL
RED
RED
LT. BLUE
P-3
P-1
P-2
P-4
ICE MAKER
LT. BLUE
IMPORTANT SAFETY NOTE
The information provided herein is designed to assist qualied repair personnel only. Untrained persons should
not attempt to make repairs due to the possibility of electrical shock. Disconnect power cord before servicing
this appliance.
IMPORTANT
If any green grounding wires are removed during servicing, they must be returned to their original position
and properly secured.
IMPORTANT: PLEASE RETURN THIS SHEET TO ITS ORIGINAL LOCATION.
PERFORMANCE DATA NO LOAD & NO DOOR OPENINGS AT 37°/0°
CONTROL SETTING
Type A with Run /
Start Capacitor
65°F (18°C) Ambient 90°F (32°C) Ambient
Operating Time 90 to 100% 100%
Freezer Temperature
-5° to 2°F
(-20° to -17°C)
-1° to 3°F
(-18° to -16°C)
Refrigerator Temperature
34° to 39°F
(1° to 4°C)
34° to 39°F
(1° to 4°C)
Low Side Pressure
-2 to 6 psig
(-14 to 41 kPa)
-2 to 6 psig
(-14 to 41 kPa)
High Side Pressure
(last 1/3 cycle)
85 to 105 psig
(586 to 724 kPa)
120 to 135 psig
(827 to 931 kPa)
Wattage (last 1/3 cycle) 30 to 50 50 to 70
Amps (running) .4 to .8 .7 to .9
Base Voltage 115 vac (127 vac max)
DEFROST SPECIFICATIONS
Cabinet Size:
27’ & 28’ SD, 22’ CD
Thermal Cutout Heater Defrost
Heater
Termination
Cut-in Cut-out Watts Ohms Cut-out
110°F
(43.3°C)
135°F
(57.2°C)
500 26.5 48°F
(8°C)
CONDENSER FAN MOTOR
Watts RPM Amps
3.1
1100 CW
Opposite Shaft
0.03 Running
FREEZER ICE MAKER SPECIFICATIONS
Electrical 115 vac (127 vac max)
Thermostat Opens at 48°F ( 9°C), Closes at 15° F ( -9°C)
Heater Voltage 115 vac
CAUTION
All electrical parts and wiring must be shielded from torch ame. DO NOT allow torch to touch
insulation; it will char at 200°F and ash ignite (burn) at 500°F. Excessive heat will distort the
plastic liner.
SYSTEM DIAGNOSTIC MODE
Activate: Press
FZ
^ and
FZ v
for up to 10 sec. simultaneously. Press
FF
^ to advance
through tests.
Deactivate: Press
FF
^ for up to 10 sec. Diagnostic Mode will automatically deactivate after 10
min. of inactivity.
Note: Silence alarm.
• Tests marked with “*” may not be applicable to this unit and will not be displayed in System DiagnosticMode.
• Tests displayed in diagnostic mode but not described below are for internal purposes only; advance through.
• View UI display for “on,” “off,” “CL,” “OP,” “SH,” “LO,” “HI” or numerical results of tests.
• Listen for operating sounds; feel for heat or air ow as appropriate to determine results of tests.
Test To activate test: Passing result
-- First Screen -- Blank UI display, no LEDs illuminated.
-- Second Screen -- All LED lights on UI illuminated.
-- Third Screen -- Blank UI display, no LEDs illuminated.
46 Humidity Sensor Activates
automatically
“OP” if open, “SH” if short. AC Heater System: Displays
%RH. DC Heater System: “HI” - heater should be on. “Lo”
- heater should be off. %RH is displayed when humidity is
between “Lo” and “HI” values; heater could be on or off.
2 Freezer
Defrost Heater
Press power on-off Freezer defrost heater on when “on”; off when “off. Evapo-
rator thermistor temperature is ashed. Watch for temp
increase with the heater on. It may take a few minutes for
the evaporator to heat up.
12 Condenser Fan Press power on-off Fan running when “on”; stopped when “off”
43 Mullion Anticon-
densation Heater
Press power on-off Flip Mullion Heater on when “on”; off when “off”
38 VCC Compressor Press power on-off Compressor on when “on”; off when “off”
13 FF Lights Press power on-off FF lights on when “on”; off when “off”
15 Freezer
Evaporator Fan
Press power on-off Press to toggle between “off”, “Lo” and “HI”. A current sen-
sor reading is ashed (units are not mA). OFF reading should
be around 2. “Lo” speed reading should settle down to
around 9. “HI” speed reading should settle down above 40.
20 FZ Lights Press power on-off FZ lights on when “on”; off when “off
22 Damper Press power on-off Perform test 15 and set fan to “HI”. Then, check for air ow
when open “OP,” and no air leaks when closed “CL.
23 FF Door Open/close FF door “CL” on UI when door closed; “OP” when open
24 FZ Door Open/close FZ door “CL” on UI when door closed; “OP” when open
29 FF Thermistor Activates
automatically
UI shows temperature sensed by FF thermistor; pass if
within 10°F of temperature measured with gauge at FF
thermistor location.
“OP” if open; “SH” if short
30 FZ Thermistor Activates
automatically
UI shows temperature sensed by FZ thermistor; pass if
within 10°F of temperature measured with gauge at FZ
thermistor location.
“OP” if open; “SH” if short
33 Ambient Therm-
istor @ Main
Board
Activates
automatically
UI shows temperature sensed at main board; pass if within
+20°F/-10°F of temperature measured with gauge at main
board location.
“OP” if open; “SH” if short
34 Ambient Therm-
istor @ UI
Activates
automatically
UI shows temperature sensed at UI; pass if within +20°F/-
10°F of temperature measured with gauge at UI location.
“OP” if open; “SH” if short
39 Freezer
Evaporator
Thermistor
Activates
automatically
UI shows temperature sensed by freezer evaporator thermis-
tor; pass if within 10°F of temperature measured with gauge
at evaporator thermistor location. “OP” if open; “SH” if short
0- Firmware
Parameters
Press power on-off Displays digit sequence; record
1- Main Board
Firmware
Press power on-off Displays digit sequence; record
3- UI Firmware Press power on-off Displays digit sequence; record
ERROR CODES SPECIAL MODES
Display Interpretation Mode Display Activate Deactivate
FZ FF FZ FF (Press for up to 10 sec. simultaneously)
-- OP Open FF
Cavity Thermistor
Manual Defrost d F FF
^
and FF v Same to
deactivate
OP -- Open FZ
Cavity Thermistor
Demo /
Showroom
77 77 FZ
^
and FF v Unplug to
deactivate
-- SH Shorted FZ
Cavity Thermistor
Sabbath Sb Sb FZ v and FF
^
Same to deactivate
SH -- Shorted FZ
Thermistor
System
Diagnostic
Blank UI display,
no LEDs
illuminated
FZ
^
and FZ v Press and hold FF
^
to deactivate
SY CF UI to Main Board
communication
failure; on start up
Current Air
Temps
FZ
Temp
FF
Temp
Default Settings
and C/F Buttons
Automatically
after 10 seconds
SY CE UI to Main Board
communication
error; after a period
of operation
Notes:
Always check for pin back-outs, pinched or damaged wires before
replacing components.
Determine whether failure is caused by the component, main control
board or wiring. Contact TID before replacing main control board.
Refer to Service Manual for additional information.
SY EF Freezer Evaporator
Fan Failure
Replace Inverter Board
Check at Inverter Board on
Compressor
(BLK and RED wires)
Is Inverter Board receiving 10-15
VAC and 1-5 VDC from Main
Control Board?
Check at Main Control Board
(BLK/WHT and RED/BLK wires)
Is Main Control Board sending
10-15 VAC and 1-5 VDC to
Inverter Board?
no
Check at the connector from the power cord
harness into the inverter board, located in
the machine compartment.
(PUR and WHT wires)
Is Inverter Board receiving 115 VAC
from power supply?
Check voltage supply.
Check and repair power
cord harness wiring and
connections.
no
Identify and repair damaged wires or
poor connections between Main Control
Board and Inverter Board.
yes
Remove inverter box from the
compressor and check resistance
across compressor winding pairs as
shown.
Is resistance across all winding
pairs equal?
Replace Compressor and
Inverter Board.
no
Check connections from Inverter
Board to Compressor
Are connections from Inverter
Board to Compressor intact?
yes
Identify and repair damaged
wires or poor connections
between Inverter Board and
Compressor.
no
VCC Resistance Check
Check resistance between terminals 1 and
2, 2 and 3, 3 and 1.
If all resistances are equal,
compressor is operative.
Replace Main Control Board.
no
yes yes
yes
VCC COMPRESSOR MOTOR RESISTANCE CHECK
FREEZER ICE MAKER INFORMATION
(Where Applicable)
Test Cycling: Remove cover by inserting screwdriver in notch
at bottom and prying cover from housing. Use screwdriver to
rotate motor gear counterclockwise until holding switch circuit
is completed. All components of ice maker should function to
complete the cycle.
Water Fill Volume: The water ll adjustment screw will
change the ll time. One full turn is equal to 20cc (.68 oz.).
The correct ll is 102 to 130cc (3.4 to 4.3 oz.). When a water
valve is replaced, the ll volume must be checked.
T
U
R
N
Mounting
Plate
Screws
Mounting
Plate
Screw
Motor
Gear
Timing
Gear
Water Fill
Adjustment
Page view 0
1 2

Summary of Contents

Page 1 - A06686901

SERVICE DATA SHEET A06686901FREEZER ICE MAKER - AUTOMATIC DEFROSTBOTTOM FREEZER - R134a POWERICE MAKERICE MAKERICE MAKERWATER VALVELINETHERMA

Page 2 - Wire Diagram A06742201

Wire Diagram A06742201ERF2500++ISOREFRIGERATORCONTROLRIBBED(NEUTRAL)NON-RIBBED(LINE)COMPRESSORGROUNDTHERMALCUT-OUTLINECAB. GROUNDRL2LINEFREEZEREVAPORA

Comments to this Manuals

No comments