NOTE
For installations requiring a longer drain hose, have a
quali ed technician install a longer drain hose (according
to your model number) available from an authorized parts
distributor. For drain systems in the oor, install a syphon
break kit available from your local hardware store.
INSTALLATION REQUIREMENTS
Installation in a Recess or Closet
If washer and dryer are installed in the same closet, door
ventilation is required: A minimum of 120 square inches
(774.2 cm²) of opening, equally divided at the top and
bottom of the door, is required. Louvered openings should
be located 3 inches (7.6 cm) from bottom and top of door.
Air openings are required to be unobstructed when a door is
installed. A louvered door with equivalent air openings for the
full length of the door is acceptable.
60 sq. in.
(387.1cm²)
3”
(7.6cm)
60 sq. in.
(387.1cm²)
3”
(7.6cm)
closet door
Drain system requirements
1 Drain capable of eliminating 17 gals (64.3 L) per minute.
2 A standpipe diameter of 1-1/4 in. (3.18 cm) minimum.
3 The standpipe height above the oor should be:
Minimum height: 39 in. (99 cm)
Maximum height: 96 in. (244 cm)
96”
(244 cm)
max.
39”
(99 cm)
min.